The
uses permitted for MC cable are governed by NEC®
Article 330 and any applicable local codes. Please refer
to NEC® Article 330 and your local authority having
jurisdiction for additional information. |
The
uses permitted for AC cable are governed by NEC
Article 320 and any applicable local codes. Please refer
to NEC Article 320 and your local authority having
jurisdiction for additional information. |
|
Type MC Metal Clad Wires Cable |
Type AC Armored Wire Cables |
AFC CABLE SYSTEMS MC METAL
CLAD AND AC ARMORED WIRE & CABLE
Type MC Metal Clad Cable Section
MC Product
Summaries
|
|
MC TUFF®
Lightweight Steel Metal Clad Cable
High Strength, Lightweight Galvanized Steel Armor
featuring ColorSpec® |
Applications
Commercial, industrial, multi-residential branch circuits and
feeder wiring-services for power, lighting, control and signal
circuits – exposed or concealed – fished, surface mounted,
embedded in plaster – environmental air-handling spaces – open
or messenger supported aerial runs – dry locations – in
hazardous locations to Class I & II Div. 2 and Class III, Div. 1
& 2 (as specified in NEC Articles 501, 502, 503) – places of
assembly – applications requiring superior EMI shielding |
|
MC TUFF® IG
Lightweight Interlocking Steel Isolated Ground Cable
High Strength, Lightweight Galvanized Steel Armor
featuring ColorSpec® |
Applications
Commercial, industrial, multi-residential branch circuits and
feeder wiring approved for MC cable requiring isolated,
redundant or dedicated grounding conductors – services for
power, lighting, control and signal circuits – exposed or
concealed – fished, surface mounted, embedded in plaster –
environmental air-handling spaces – open or messenger supported
aerial runs – dry locations – in hazardous locations to Class I
& II Div. 2 and Class III, Div. 1 & 2 (as specified in NEC
Articles 501, 502, 503) – places of assembly |
|
Type MC Steel Metal Clad Cable (8 AWG-2 –
4/0 AWG-4 )
Galvanized Steel Armor |
Applications
Commercial, industrial, multi-residential branch circuits and
feeder wiring-services for power, lighting, control and signal
circuits – exposed or concealed – fished, surface mounted,
embedded in plaster – environmental air-handling spaces – open
or messenger supported aerial runs – dry locations – in
hazardous locations to Class I & II Div. 2 and Class III, Div. 1
& 2 (as specified in NEC Articles 501, 502, 503) – places of
assembly – applications requiring superior EMI shielding |
|
MC-Lite®Metal Clad Cable
Aluminum Interlocking Armor featuring ColorSpec® |
Applications
Commercial, industrial, multi-residential branch circuits and
feeder wiring – services for power, lighting, control and signal
circuits – exposed or concealed – fished, surface mounted,
embedded in plaster – environmental air handling spaces – open
or messenger supported aerial runs – dry locations – in
hazardous locations to Class I & II Div. 2 and Class III, Div. 1
& 2 (as specified in NEC Articles 501, 502, 503) – places of
assembly |
|
Fire Alarm/Control Cable™
Galvanized Interlocking Steel Armor Color Coded Red
featuring ColorSpec® |
Applications
Fire alarm wiring or remote control hook-up connecting main fire
alarm control panel with pull stations, smoke detectors and
alarms – remote control circuits from magnetic motor starters,
contactors, relays and signals – exposed, concealed, in cable
trays, ducts, plenums or other environmental air-handling spaces
– FPLP – in hazardous locations up to Class I & II, Div. 2 and
Class III, Div. 1 & 2 (as specified in NEC Articles 501, 502,
503) |
|
Super Neutral Cable®
Galvanized Interlocking Steel or (optional) Aluminum Armor |
Applications
Branch circuit and feeder wiring for computers, programmable
controllers, electronic discharge lighting, office machines and
other electronic equipment that introduce additive harmonic
currents from nonlinear switching loads – compatible with most
modular office furniture – under raised floors, above suspended
ceilings, in environmental air-handling spaces – applications
requiring superior EMI shielding (steel armor only)
Product Specification Refer to page: Super Neutral Cable® 17 |
|
ParkingDeck/Lot Cable™
PVC JacketedMetal Clad Cable
Galvanized Steel Armor with PVC Jacket |
Applications
Branch circuit and feeder wiring for lighting, control and
signal circuits in wet, dirty or oily locations – buried
directly in earth or concrete – surface mounted or trenched –
parking deck or parking lot applications – golf courses, ski
mountains, docks, marinas, pumping stations and stadium lighting
– continuous runs to outdoor or underground swimming pool
motors, pumps and related equipment (per NEC 680) – fished,
exposed or concealed, in cable trays – in direct sunlight and
hazardous locations up to Class I & II, Div. 2 and Class III,
Div. 1 & 2 (NEC Articles 501, 502, 503) |
|
|
Home Run Cable®
Galvanized Steel Armor |
Applications
Multi-conductor runs from panel board to junction box for power,
lighting, control and signal circuits – repetitive homeruns in
multi-story hotels, dormitories, commercial office buildings and
warehouse applications – conductors must be derated per NEC
Table 310.15(B)(2)(a) – exposed or concealed, fished – in cable
trays and environmental air-handling spaces |
The
uses permitted for MC cable are governed by NEC®
Article 330 and any applicable local codes. Please refer
to NEC® Article 330 and your local authority having
jurisdiction for additional information. |
Type AC
Armored Section
Product Summaries
AFC
manufactures two varieties of armored (Type AC) cables, standard
AC cable
and HCF, Health Care Facilities Cable, both featuring the
ColorSpec ID System.
|
|
Type AC-90® & Type AC-Lite® Armored Cable
Galvanized Steel or Aluminum Armor Color-Coded Black* |
Applications
Commercial, industrial, multi-residential branch circuits and
feeder wiring – services for power, lighting, control and signal
circuits – exposed or concealed – surface mounted, embedded in
plaster finish on brick or other masonry (except wet or damp
locations) – fished or run in air voids of masonry block or tile
walls – under raised floors, above suspended ceilings and in
other environmental air- handling spaces |
|
HCF-90® & HCF-Lite® Health Care Facilities
Cable
Galvanized Steel or Aluminum Armor Color-Coded Green* |
Applications
Branch circuits and feeders in areas of patient care in
hospitals, nursing homes, outpatient facilities, dental offices,
clinics and medical centers (other than hazardous anesthetizing
locations) – data processing systems – places of assembly –
under raised floors, above suspended ceilings and in other
environmental air-handling spaces – exposed or concealed,
surface mounted or fished – any application approved for AC
cable requiring an isolated or redundant ground |
The
uses permitted for AC cable are governed by NEC
Article 320 and any applicable local codes. Please refer
to NEC Article 320 and your local authority having
jurisdiction for additional information. |
mc, ac, metal, clad, armor, armored, cable, wire, cables,
wires, cabling, wiring, health, care, facility, health-care, commercial,
residential, multi, industrial, branch, feeder, circuits, galvanized,
steel, aluminum, hospital, hospitals, nursing, home, homes, data,
processing, center, power, lighting, control, plenum, fplp, fire, alarm
alarms, pull, station, stations, smoke, detector, detectors, plenum,
air, handling, space, spaces, afc, light, weight, light-weight,
lightweight, amour, armoured, parking, deck, decks, lot,
The uses permitted for AC cable are
governed by NEC
Article 320 and any applicable local codes. Please refer
to NEC Article 320 and your local authority having
jurisdiction for additional information. |
The uses permitted for MC cable are
governed by NEC®
Article 330 and any applicable local codes. Please refer
to NEC® Article 330 and your local authority having
jurisdiction for additional information. |
Manufacturer and/or distributor cannot guarantee performance
because we are unable to control and ensure the proper use.
Manufacturer and/or distributors warrant only that
products substantially conform to the published
specifications in effect at the time of sale and are
substantially free of defects in material and workmanship.
There are no warranties which extend beyond the description
on the face hereof. Manufacturer and/or distributors
expressly disclaim any and all other warranties, including
any warranty of fitness for a particular purpose and/or
warranty of merchantability which might otherwise be
applicable. In the event of a manufacturing defect,
buyer’s remedy is strictly limited to refund of the purchase
price or replacement. Buyer specifically acknowledges
waiver of any claim against either manufacturer or any
distributor regarding consequential or incidental damages to
person or property, including without limitation damages for
loss of use, lost time, loss of profits, lost income or
other incidental or consequential damages. Manufacturer
and/or distributor reserve the right to make specification
and price changes without prior notice or subsequent
obligation. Trademarks and Copyrights are the property of
their respective owner[s]. Pictures may not represent actual
products and are for general representational purposes. |
|