midsouthglobal.net

MC Metal Clad and AC Armored Cables

 

1-800-843-6036

 Click Here to Email Us

OnLine Order Form at midsouthelectronics.com

     

Supported Browsers IE, SAFARI, CHROME

   Home Page

Metal Clad & Armored Cable Index

More MC Metal Clad and AC Armored Cables

  
 

Parking Lot Deck MC Connectors

Galvanized Steel Armor with PVC Jacket wire cable wires cables parking deck decks park lot lots Branch circuit and feeder wiring for lighting, control and signal circuits in wet, dirty or oily locations buried directly in earth or concrete surface mounted or trenched  parking deck or parking lot applications  golf courses, ski mountains, docks, marinas, pumping stations and stadium lighting continuous runs to outdoor or underground swimming pool motors, pumps and related equipment (per NEC 680) –fished, exposed or concealed, in cable trays

Parking Lot Deck Type MC Cable

Galvanized Interlocking Steel Armor Color Coded Red fplp plenum fire alarm mc wire cable wires cables wiring cabling Fire alarm wiring or remote control hook-up connecting main fire alarm control panel with pull stations, smoke detectors and alarms remote control circuits from magnetic motor starters, contactors, relays and signals  exposed, concealed, in cable trays, ducts, plenums

FIRE ALARM MC

TYPE MC METAL CLAD WIRE & CABLE Home Run Cable®   Multi-Conductor  multiconductor  multi conductor
Repetitive cabling wiring homeruns home run in multi-story hotels, motels, dormitories, commercial office buildings

Conductor Insulation: THHN THWN

afc wire cable wires cables home run Galvanized Steel Armor Multi-conductor runs from panel board to junction box for power, lighting, control and signal circuits repetitive homeruns in multi-story hotels, dormitories, commercial office buildings and warehouse applications  conductors must be derated per NEC Table 310.15(B)(2)(a) exposed or concealed, fished  in cable trays and environmental air-handling spaces

Home Run Cable®
Galvanized Steel Armor

Applications
Multi-conductor runs from panel board to junction box for power, lighting, control and signal circuits – repetitive homeruns in multi-story hotels, dormitories, commercial office buildings and warehouse applications – conductors must be derated per NEC Table 310.15(B)(2)(a) – exposed or concealed, fished – in cable trays and environmental air-handling spaces

Specification Description

Armor: Galvanized Interlocking Steel* Strip Conductors:  Solid Copper
Conductor:  THHN/THWN
Insulation
Assembly:  Polypropylene Tape
Covering
Maximum
Temperature Rating: 90°C (dry)
Grounding:  One grounding means — Insulated Green Grounding Conductor (additional grounding conductors optional**)
Maximum Voltage Rating: 600V

References & Ratings
• U.L. 83, 1479, 1569, 1581, File Reference E80042
• NEC 230.43, 300.22(C), 392, 396, 330, 645
• Federal Specification A-A-59544 (formerly J-C-30B)
• Cable Tray installations per NEC
• U.L. Classified 1, 2 and 3-hour Through-Penetration Fire Wall
File R-14929
• Environmental Air-Handling Space installation
• Conductors must be derated per NEC Table 310.15(B)(2)(a)

WEB PRICING PER 1000FT ** CALL US FOR VOLUME DISCOUNTS

Part# / Reel Length Trade Size Ground Conductor Gauge Web Price Per 1000FT
1901-45-00 / 500' 12-6 Solid 12 email us
1901-60-00 / 1000' 12-6 Solid 12 email us
1902-45-00 / 500' 12-8 Solid 12 email us
1902-60-00 / 1000' 12-8 Solid 12 email us
1911-45-00 / 500' 10-6 Solid 10 email us
1911-60-00 / 1000' 10-6 Solid 10 email us
1905-45-00 / 500' 10-8 Solid 10 email us
1905-60-00 / 1000' 10-8 Solid 10 email us
1927-99-00 / †† Cut to Length-Minimums Apply 10-12 Solid 10 email us
1928-99-00 / †† Cut to Length-Minimums Apply 10-16 Solid 10 email us

PRICES SUBJECT TO CHANGE WITHOUT NOTICE.

INVENTORY SUBJECT TO PRIOR SALE.

INVENTORY CAN BE DISCONTINUED WITHOUT NOTICE.

Note: All dimensions and weights subject to normal manufacturing tolerances.
Non-stock items require lead time and minimum quantity.
* Aluminum available by special order and subject to lead times and minimum quantities.
** Special order, subject to lead times and minimum quantities.
†† Cut to order.

Stocking Sizes Color Codes:
Conductors 120 Volt Colors
6 black, black/silver, red, red/silver, white, white/silver
8 black, black/silver, red, red/silver, blue, blue/silver, white, white/silver
12 3 black, 3 red, 3 blue, 3 white; each color numbered 1-3
16 4 black, 4 red, 4 blue, 4 white; each color numbered 1-4

 multiconductor, multi, conductor, conductors, multi-conductor, mc, metal, clad, wire, cable, wires, cables, wiring, cabling, size, gauge, awg, 12, 10, 6, 8, 12, 16, 12awg, 10awg, thhn, thwn, solid, copper, power, lighting, control, signal, circuit, circuits, hotel, hotels, motel, motels, office, building, buildings, warehouse, home, run, homerun, home-run, afc,

The uses permitted for MC cable are governed by NEC®
Article 330 and any applicable local codes. Please refer
to NEC® Article 330 and your local authority having
jurisdiction for additional information.

Manufacturer and/or distributor cannot guarantee performance because we are unable to control and ensure the proper use. Manufacturer and/or distributors warrant only that products substantially conform to the published specifications in effect at the time of sale and are substantially free of defects in material and workmanship. There are no warranties which extend beyond the description on the face hereof. Manufacturer and/or distributors expressly disclaim any and all other warranties, including any warranty of fitness for a particular purpose and/or warranty of merchantability which might otherwise be applicable. In the event of a manufacturing defect, buyer’s remedy is strictly limited to refund of the purchase price or replacement. Buyer specifically acknowledges waiver of any claim against either manufacturer or any distributor regarding consequential or incidental damages to person or property, including without limitation damages for loss of use, lost time, loss of profits, lost income or other incidental or consequential damages. Manufacturer and/or distributor reserve the right to make specification and price changes without prior notice or subsequent obligation. Trademarks and Copyrights are the property of their respective owner[s]. Pictures may not represent actual products and are for general representational purposes.