TYPE MC Metal Clad Wire Cable Parking Deck Lot UL Listed for Concrete Encasement & Direct Burial
Branch circuit and feeder wiring for:
Lighting Control |
Signal Circuits |
Wet Dirty Oily Locations |
Direct Burial In Concrete & Earth |
Parking Deck Lot Apps |
Golf Courses & Ski Mountains |
Boat Docks & Marinas |
Pumping Stations |
Stadium Lighting |
|
|
ParkingDeck/Lot Cable™
PVC JacketedMetal Clad Cable
Galvanized Steel Armor with PVC Jacket
|
Applications
Branch circuit and feeder wiring for lighting, control and signal circuits in wet, dirty or oily locations – buried directly in earth or concrete – surface mounted or trenched – parking deck or parking lot applications – golf courses, ski mountains, docks, marinas, pumping stations and stadium lighting – continuous runs to outdoor or underground swimming pool motors, pumps and related equipment (per NEC 680) – fished, exposed or concealed, in cable trays – in direct sunlight and hazardous locations up to Class I & II, Div. 2 and Class III, Div. 1 & 2 (NEC Articles 501, 502, 503)
|
Specification Parking Deck/Lot Cable
|
Armor & Jacket: Galvanized Interlocking Steel Strip with gray PVC jacket. Other jacket colors available by
special order |
Conductors: Solid/Stranded Copper (see below) |
Conductor Insulation: THHN/THWN**
|
Assembly Covering: Polypropylene Tape |
Maximum Temperature Rating:
90°C (dry); 75°C (wet)
|
Grounding: Insulated Green Grounding Conductor |
Neutral Conductors: White for 120V circuits
Gray for 480Y/277V circuits |
Maximum Voltage Rating: 600V
|
|
References & Ratings
- U.L. 66, 83, 1479, 1569, 1581, File Reference E80042
- NEC 230.43, 300.5, 392, 396.10(A), 330, 501, 502, 503,
511.7, 513.7(A), 514.7, 515.7(A), 516.7(A), 680.21(A)
- Federal Specification A-A-59544 (formerly J-C-30B)
- Passes 210,000 BTU Vertical Tray Flame Test
- U.L. listed for Cable Tray use and FT4
- U.L. listed for Concrete Encasement
- U.L. listed Sunlight Resistant
- U.L. listed Oil Resistant II
- Hazardous locations up to Class I & II, Div. 2 and Class III,
Div. 1 & 2 (NEC Articles 501, 502, 503
|
|
WEB PRICING PER 1000FT
PART #'S |
PART #'S |
TRADE SIZE |
Ground
AWG
|
WEB PRICE
1000FT
|
Coil -250FT |
Reel - 1000FT |
|
|
|
120 VOLT |
2304-42-00 |
2304-60-00 |
12-2 Solid |
12 |
EMAIL US |
2305-42-00 |
2305-60-00 |
12-3 Solid |
12 |
EMAIL US |
2306-42-00 |
2306-60-00 |
12-4 Solid |
12 |
EMAIL US |
2307-42-00 |
2307-60-00 |
10-2 Solid |
10 |
EMAIL US |
2308-42-00 |
2308-60-00 |
10-3 Solid |
10 |
EMAIL US |
2309-42-00 |
2309-60-00 |
10-4 Solid |
10 |
EMAIL US |
2316-99-00 |
2316-99-00 |
8-3 Stranded†† Cut to Length |
10 |
EMAIL US |
2320-99-00 |
2320-99-00 |
6-3 Stranded†† Cut to Length |
8 |
EMAIL US |
|
|
Cut to Length Minimums Apply* |
|
|
480Y/277 Volt |
|
|
|
2304-42-01 |
2304-60-01 |
12-2 Solid (brown) |
12 |
EMAIL US |
2305-42-01 |
2305-60-01 |
12-3 Solid (brown, orange) |
12 |
EMAIL US |
2306-42-01 |
2306-60-01 |
12-4 Solid (brown, orange, yellow) |
12 |
EMAIL US |
2307-42-01 |
2307-60-01 |
10-2 Solid (brown) |
10 |
EMAIL US |
2308-42-01 |
2308-60-01 |
10-3 Solid (brown, orange) |
10 |
EMAIL US |
2309-42-01 |
2309-60-01 |
10-4 Solid (brown, orange, yellow) |
10 |
EMAIL US |
mc, metal, clad, wire, cable, wires, cables, wiring, cabling, park, parking, deck, decks, lot, lots, golf, course, courses, ski, mountain, mountains, skiing, boat, boating, boats, marina, dock, docks, pump, pumping, station, stations, stadium, light, lights, lightings, lighting, swimming, pool, pools, motor, motors, oil, resistant, direct, burial, concrete, encasement, tray, 120, volt, 120v, 480y, 277v, circuit, circuits. 12, 10, 8 gauge, size, awg,
The uses permitted for MC cable are governed by NEC®
Article 330 and any applicable local codes. Please refer
to NEC® Article 330 and your local authority having
jurisdiction for additional information.
|
Manufacturer and/or distributor cannot guarantee performance because we are unable to control and ensure the proper use. Manufacturer and/or distributors warrant only that products substantially conform to the published specifications in effect at the time of sale and are substantially free of defects in material and workmanship. There are no warranties which extend beyond the description on the face hereof. Manufacturer and/or distributors expressly disclaim any and all other warranties, including any warranty of fitness for a particular purpose and/or warranty of merchantability which might otherwise be applicable. In the event of a manufacturing defect, buyer’s remedy is strictly limited to refund of the purchase price or replacement. Buyer specifically acknowledges waiver of any claim against either manufacturer or any distributor regarding consequential or incidental damages to person or property, including without limitation damages for loss of use, lost time, loss of profits, lost income or other incidental or consequential damages. Manufacturer and/or distributor reserve the right to make specification and price changes without prior notice or subsequent obligation. Trademarks and Copyrights are the property of their respective owner[s]. Pictures may not represent actual products and are for general representational purposes. |
|